Logiball Securimax type A & B plugs


The Logiball Securimax inflatable pipe plugs are designed with high safety factors such as a two ply cross-biased reinforced SBR rubber sleeve, anchoring device and end plate retaining device for a maximum strength.

These sewer plugs can be used for low pressure line acceptance testing, plugging and flow control needs for pipe sizes 4″ to 36″.

Every inflatable plug must pass a severe pressure test and is identified by a serial number. With each Logiball Securimax pipe plug, we supply the test certificate and a leaflet describing the features of the sewer plug and providing information on its safe use.

All Logiball Securimax plugs can be factory resleeved.

Model A: No flow-thru
Model B: 2″ flow-thru hose
Model C: Two 1/2″ flow-thru hoses

 

TECHNICAL SPECIFICATIONS:

Logiball Securimax Plugs Model A & Model B
Product # By-pass
Size*
Pipe Size
Recommended
Inflation Pressure** Outside Diameter Weight Length
inches mm inches mm P.S.I. KPA inches mm lbs kg inches mm
4-8B 1/2″ 13 4 to 8 100-200 45 310 3.5 90 6 3 18.5 470
5-10A
5-10B
n/a
2″
n/a
50
5 to 10 125-250 45 310 4.8 120 15 7 26 660
7-12A
7-12B
n/a
2″
n/a
50
7 to 12 175-300 35 240 6.6 170 26 12 28.5 725
9-16A
9-16B
n/a
2″
n/a
50
9 to 16 225-400 35 240 8.6 220 37 17 30 762
11-21A
11-21B
n/a
2″
n/a
50
11 to 21 280-525 35 240 10.75 275 50 23 35.5 900
13-24A
13-24B
n/a
2″
n/a
50
13 to 24 330-600 35 240 12.75 325 66 30 39 990
17-30A
17-30B
n/a
2″
n/a
50
17 to 30 430-760 25 170 16.6 425 160 73 58 1470
19-36A
19-36B
n/a
2″
n/a
50
19 to 36 480-900 20 140 18.75 480 195 88 64 1625

* Larger by-pass available for 9-16 and up are available.
** At these pressures, the plugs will make a tight seal and safely withstand a back pressure of 5 P.S.I. or
12 feet of water in structurally sound and clean pipes.

Push-type Logiball plugs for smaller pipe sizes are also available.
Safety inflation Systems are available.

 

 

 

Brochure

Our commitment to safety