The lateral packers are operated from the truck with a control panel. The control panel is used to:
- Control the operation of the different motors of the lateral packers.
- Control the inflation and vent/vacuuming of the lateral plug
- Provide manual valves to set the pressure regulators and to cut off the air supply to verify for slow leaks in the system.
- Provide a switch controlled 110 volt 15 amp outlet for the vacuum pump.
Dimension: 20.25″ x 11.75″ x 6.5″
| Motor used to Rotate the Lateral Packers | |||
| Size of Packer | Type of Motor | Safe Recommended Voltage | |
| 6″ | 150mm | 0-24 volts dc | 0-24 volts dc |
| 8″ to 12″ | 200 to 300 mm | 0-90 volts dc | 0-48 volts dc |
| 15″ and over | 375mm & over | 0-130 volts dc | 0-48 volts dc |