- Never let anybody unaware of security
instructions use pneumatic plugs.
- Never enter a confined space without
verifying for harmful gases. The plugging of a live conduit may cause
gas formation and accumulation.
- Control the inflation pressure and the
back pressure. Always inflate the pipe plug from a safe distance using an
extension hose fitted with a pressure gauge, a pressure regulator, a preset
safety valve and a shut-off valve.
- Do not rely on friction to withstand a
back pressure when important material damages and people's safety are at
stake. Always secure
the plug.
- Never stand close to an inflated plug
without the protection of a bulkhead designed to guarantee the security in
the event of a failure or dislodgment of the plug.
- Test the plug, the inflation hose and
the controls before each use and keep a record of the tests.
-
Refer to the pipe plug information leaflet to
supplement this safety measures list.
|