Segmental testing is used to identify and
pinpoint leaking joints in collection systems. The
inflatable plugs are winched down the line and positioned to
straddle the joint to be tested. Once the plugs are inflated
a low pressure air test is performed to verify the integrity
of the joint.
Flexible sewer plugs. |

Kits available for 6" to
36" |